About TTConnect 616
TTConnect 616 Configurable Switch is designed for application development and the support of Ethernet in-vehicle network architectures.
TTConnect 616 was specifically developed for vehicles and machines used in rugged operating environments and at extreme operating temperatures. It is protected by a proven, robust and compact housing, designed for the off-highway and agricultural industry.
Product Datasheets
Supported Use Cases
- Connects sensors and cameras to displays and control units
- High-speed backbone for connecting vehicle domains
- Media converter
- Fast SW updates, enhanced debugging, logging and diagnostic features
Product Overview
Product | CPU | Number I/Os | Field Bus / Interfaces | Safety Certification / SIL Level | Programming Support |
---|---|---|---|---|---|
N4 – Network Controller |
Up to 11970 DMIPS on 4x Arm Cortex- A53 and 3x Arm Cortex-M7 |
2 Outputs 1 Wake-up Input |
1x1000BASE-T1, 6x100BASE-T1, 1x100BASE-TX, 12xCAN (FD), 2xLIN |
ISO 26262 ASIL B |
Yocto GNU/Linux and other POSIX OS possible AUTOSAR Classic envirionment |
TTC 2310 |
3 cores 32-bit, 300 MHz |
20 inputs (analog, digital, timer, SENT) 36 outputs |
4 x CAN 1 x CAN ISOBUS 1 x CAN (wake-up capable) 1 x LIN |
IEC 61508 SIL 2 EN ISO 13849 PL d ISO 25119 AgPL d SRL2 ISO 26262 ASIL C ISO 19014 MPL d |
C programming (Matlab Simulink I/O Blocklib available) CODESYS® Safety SIL 2 including support for CANopen Safety Master |
TTC 2380 |
3 cores 32-bit, 300 MHz |
20 inputs (analog, digital, timer, SENT) 40 outputs |
4 x CAN 1 x CAN ISOBUS 1 x CAN (wake-up capable) 2 x Ethernet 1 x LIN |
IEC 61508 SIL 2 EN ISO 13849 PL d ISO 25119 AgPL d SRL2 ISO 26262 ASIL C ISO 19014 MPL d |
C programming (Matlab Simulink I/O Blocklib available) CODESYS® Safety SIL 2 including support for CANopen Safety Master |
TTC 2385 |
3 cores32-bit, 300 MHz |
20 inputs (analog, digital, timer, SENT) 40 outputs |
4 x CAN 1 x CAN ISOBUS 1 x CAN (wake-up capable) 2 x BroadR-Reach* 1 x LIN |
IEC 61508 SIL 2 EN ISO 13849 PL d ISO 25119 AgPL d SRL2 ISO 26262 ASIL C ISO 19014 MPL d |
C programming (Matlab Simulink I/O Blocklib available) CODESYS® Safety SIL 2 including support for CANopen Safety Master |
TTC 2390 |
6 cores 32-bit, 300 MHz |
20 inputs (analog, digital, timer, SENT) 40 outputs |
4 x CAN 1 x CAN ISOBUS 1 x CAN (wake-up capable) 2 x BroadR-Reach* 1 x LIN |
IEC 61508 SIL 2 EN ISO 13849 PL d ISO 25119 AgPL d SRL2 ISO 26262 ASIL C ISO 19014 MPL d |
C programming (Matlab Simulink I/O Blocklib available) CODESYS® Safety SIL 2 including support for CANopen Safety Master |
TTC 590 |
32-bit, 180 MHz |
36 inputs (analog, digital, timer) 60 outputs (36 x PWM with current feedback) |
6 x CAN 1 x CAN ISOBUS 1 x BroadR-Reach® 1 x LIN 1 x RS-232 |
EN 61508 SIL 2 EN ISO 13849 PL d ISO 25119 AgPL d* ISO 26262 ASIL C* |
CODESYS® Safety SIL 2 C programming (Matlab Simulink I/O Blocklib available) SAFERTOS® integration |
TTC 580 |
32-bit, 180 MHz |
36 inputs (analog, digital, timer) 60 outputs (36 x PWM with current feedback) |
7 x CAN 1 x Ethernet 1 x LIN 1 x RS-232 |
EN 61508 SIL 2 EN ISO 13849 PL d ISO 25119 AgPL d* ISO 26262 ASIL C* |
CODESYS® Safety SIL 2 C programming (Matlab Simulink I/O Blocklib available) SAFERTOS® integration |
TTC 540 |
32-bit 180 MHz |
52 inputs (analog, digital, timer) 44 outputs (28 x PWM with current feedback) |
4 x CAN |
EN 61508 SIL 2 EN ISO 13849 PL d ISO 25119 AgPL d* ISO 26262 ASIL C* |
CODESYS® Safety SIL 2 C programming (Matlab Simulink I/O Blocklib available) SAFERTOS® integration |
TTC 510 |
32-bit, 180 MHz |
44 inputs (analog, digital, timer) 40 outputs (16 x PWM with current feedback) |
3 x CAN 1 x LIN |
EN 61508 SIL 2 EN ISO 13849 PL d ISO 25119 AgPL d* ISO 26262 ASIL C* |
CODESYS® Safety SIL 2 C programming (Matlab Simulink I/O Blocklib available) SAFERTOS® integration |
TTC 508 |
32-bit, 180 MHz |
44 inputs (analog, digital, timer) 32 outputs (10 x PWM with current measurement) |
2 x CAN 1 x CAN ISOBUS 1 x BroadR-Reach® |
EN 61508 SIL 2 EN ISO 13849 PL d ISO 25119 AgPL d* ISO 26262 ASIL C* |
C-programming (Matlab Simulink I/O Blocklib available) |
TTC 94 |
16/32 bit 80 MHz |
28 inputs (analog & digital) 20 outputs (8 x PWM, 4 PWM with current feedback) |
4 x CAN 1 x LIN 1 x RS 232 |
EN ISO 13849 PL d* |
CODESYS® C-programming (Matlab Simulink I/O Blocklib available) |
TTC 32S |
16-bit, 80 MHz |
14 inputs (analog & timer) 16 outputs (digital, voltage, PVG and 8x PWM, 6 with current feedback) |
2 x CAN | EN ISO 13849 PL d* | C-programming (Matlab Simulink I/O Blocklib available) |
TTC 30SH |
16-bit 80 MHz |
14 inputs (analog & timer), 16 outputs (digital, voltage, PVG and 8x PWM, 6 with current feedback) |
1 x CAN | EN ISO 13849 PL c | C-programming (Matlab Simulink I/O Blocklib available) |
TTConnect 616CS |
3 cores 32 bit 300 MHz |
Not applicable |
6 x 100BASE-T1 BroadR-Reach® 1 x 100BASE-TX Ethernet |
Not applicable |
Not applicable „plug & play“ solution via TTC Downloader |
*available for C-programming only |
Product | CPU | Number I/Os | Field Bus / Interfaces | Safety Certifcation / SIL Level | Programming Support |
---|---|---|---|---|---|
TTC 48XS |
16/32 bit, 80 MHz |
28 inputs (analog & digital), 20 outputs (8x PWM) |
1 x CAN | EN ISO 13849 PL d |
Slave software preinstalled – attached to a master controller via CANopen as slave unit |
TTC 30XSH |
16/32 bit, 80 MHz |
14 inputs (analog & timer), 16 outputs (digital, voltage, PVG and 8 x PWM, 6 with current feedback) |
1 x CAN | EN ISO 13849 PL c |
Slave software preinstalled – attached to a master controller via CANopen Safety as slave unit |
Service Area
For further information, including price and availability, please contact products@tttech-auto.com.