Powerful safety controllers for high-end applications
The TTC 500 family consists of high-end safety control units designed to satisfy upcoming needs for a wide range of high-end applications in the automotive industry.
It can be used as platform for vehicle prototyping and development as well as a powerful control unit for series programs e.g. as VCU, for (electric) power train applications or vehicle dynamics control systems – even in low volume programs.
The extensive I/O set with various configuration options makes the TTC 500 controllers suitable for a wide range of use cases: For example, a group of 8 I/O pins can be individually configured for use as voltage output, digital output or analog input. Commissioning time is also improved by utilizing Ethernet for downloading and debugging purposes.
The freely programmable high-end controllers with the powerful dual-core ARM Cortex®-R4 lockstep processor are protected by a compact, automotive-style housing suited for harsh environments. The controllers fulfill safety requirements of IEC 61508 SIL 2, EN ISO 13849 and ISO 26262. They can be programmed either in C (with a MATLAB Simulink BlockLib available on request), CODESYS® or SAFERTOS. The safety certified CODESYS® Safety SIL 2 with its validated compiler and code generator speeds up application development significantly.
The majority of run-time tests that are needed to achieve the diagnostic coverage required for ISO 26262 are performed in hardware by the dual-core lockstep CPU and its safety companion. Therefore, almost the full processor power is available for the application. The available memory protection mechanisms allow to execute safety-related and non-safety-related software on the same ECU with freedom from interference.
Key Benefits
32 bit dual-core lockstep CPU with 180 MHz and floating-point unit
Extensive I/O set with multiple software configuration options per pin
Open programming environment for C, CODESYS® and SAFERTOS
MATLAB Simulink I/O block library available
ISO 26262 (ASIL C), IEC 61508 (SIL 2) and EN ISO 13849 (PL d) certified
Connectivity: up to 7 CAN, RS232 and LIN interfaces for vehicle interaction
Ethernet interface for fast flashing times (TTC 580)
Automotive Ethernet interface / Broad-R-Reach® connectivity (TTC 590)
ECU Starter Kit:
Dedicated starter kits are available for working with the ECU. Each kit will be delivered in a handy case and offers the advantage of fast orientation and development of the TTC ECU. The user benefits from cost savings compared to the individual prices of the contained products.
The ECU Starter Kit contains:
-
1 x ECU with open housing (unsealed) for C-programming
-
1 x JTAG-Adapter (only SAFERTOS® kit)
-
1 x Complete Connector / Cable Harness
-
1 x Interface Board KIT
-
1 x Data cable
-
1 x PCAN USB Adapter with driver and software
-
1 x Ethernet USB Adapter with driver and software (TTC 590, TTC 580)
-
1 x USB with documentation and software
Product Overview
Product | CPU | Number I/Os | Field Bus / Interfaces | Safety Certification / SIL Level | Programming Support |
---|---|---|---|---|---|
N4 – Network Controller |
Up to 11970 DMIPS on 4x Arm Cortex- A53 and 3x Arm Cortex-M7 |
2 Outputs 1 Wake-up Input |
1x1000BASE-T1, 6x100BASE-T1, 1x100BASE-TX, 12xCAN (FD), 2xLIN |
ISO 26262 ASIL B |
Yocto GNU/Linux and other POSIX OS possible AUTOSAR Classic envirionment |
TTC 2310 |
3 cores 32-bit, 300 MHz |
20 inputs (analog, digital, timer, SENT) 36 outputs |
4 x CAN 1 x CAN ISOBUS 1 x CAN (wake-up capable) 1 x LIN |
IEC 61508 SIL 2 EN ISO 13849 PL d ISO 25119 AgPL d SRL2 ISO 26262 ASIL C ISO 19014 MPL d |
C programming (Matlab Simulink I/O Blocklib available) CODESYS® Safety SIL 2 including support for CANopen Safety Master |
TTC 2380 |
3 cores 32-bit, 300 MHz |
20 inputs (analog, digital, timer, SENT) 40 outputs |
4 x CAN 1 x CAN ISOBUS 1 x CAN (wake-up capable) 2 x Ethernet 1 x LIN |
IEC 61508 SIL 2 EN ISO 13849 PL d ISO 25119 AgPL d SRL2 ISO 26262 ASIL C ISO 19014 MPL d |
C programming (Matlab Simulink I/O Blocklib available) CODESYS® Safety SIL 2 including support for CANopen Safety Master |
TTC 2385 |
3 cores32-bit, 300 MHz |
20 inputs (analog, digital, timer, SENT) 40 outputs |
4 x CAN 1 x CAN ISOBUS 1 x CAN (wake-up capable) 2 x BroadR-Reach* 1 x LIN |
IEC 61508 SIL 2 EN ISO 13849 PL d ISO 25119 AgPL d SRL2 ISO 26262 ASIL C ISO 19014 MPL d |
C programming (Matlab Simulink I/O Blocklib available) CODESYS® Safety SIL 2 including support for CANopen Safety Master |
TTC 2390 |
6 cores 32-bit, 300 MHz |
20 inputs (analog, digital, timer, SENT) 40 outputs |
4 x CAN 1 x CAN ISOBUS 1 x CAN (wake-up capable) 2 x BroadR-Reach* 1 x LIN |
IEC 61508 SIL 2 EN ISO 13849 PL d ISO 25119 AgPL d SRL2 ISO 26262 ASIL C ISO 19014 MPL d |
C programming (Matlab Simulink I/O Blocklib available) CODESYS® Safety SIL 2 including support for CANopen Safety Master |
TTC 590 |
32-bit, 180 MHz |
36 inputs (analog, digital, timer) 60 outputs (36 x PWM with current feedback) |
6 x CAN 1 x CAN ISOBUS 1 x BroadR-Reach® 1 x LIN 1 x RS-232 |
EN 61508 SIL 2 EN ISO 13849 PL d ISO 25119 AgPL d* ISO 26262 ASIL C* |
CODESYS® Safety SIL 2 C programming (Matlab Simulink I/O Blocklib available) SAFERTOS® integration |
TTC 580 |
32-bit, 180 MHz |
36 inputs (analog, digital, timer) 60 outputs (36 x PWM with current feedback) |
7 x CAN 1 x Ethernet 1 x LIN 1 x RS-232 |
EN 61508 SIL 2 EN ISO 13849 PL d ISO 25119 AgPL d* ISO 26262 ASIL C* |
CODESYS® Safety SIL 2 C programming (Matlab Simulink I/O Blocklib available) SAFERTOS® integration |
TTC 540 |
32-bit 180 MHz |
52 inputs (analog, digital, timer) 44 outputs (28 x PWM with current feedback) |
4 x CAN |
EN 61508 SIL 2 EN ISO 13849 PL d ISO 25119 AgPL d* ISO 26262 ASIL C* |
CODESYS® Safety SIL 2 C programming (Matlab Simulink I/O Blocklib available) SAFERTOS® integration |
TTC 510 |
32-bit, 180 MHz |
44 inputs (analog, digital, timer) 40 outputs (16 x PWM with current feedback) |
3 x CAN 1 x LIN |
EN 61508 SIL 2 EN ISO 13849 PL d ISO 25119 AgPL d* ISO 26262 ASIL C* |
CODESYS® Safety SIL 2 C programming (Matlab Simulink I/O Blocklib available) SAFERTOS® integration |
TTC 508 |
32-bit, 180 MHz |
44 inputs (analog, digital, timer) 32 outputs (10 x PWM with current measurement) |
2 x CAN 1 x CAN ISOBUS 1 x BroadR-Reach® |
EN 61508 SIL 2 EN ISO 13849 PL d ISO 25119 AgPL d* ISO 26262 ASIL C* |
C-programming (Matlab Simulink I/O Blocklib available) |
TTC 94 |
16/32 bit 80 MHz |
28 inputs (analog & digital) 20 outputs (8 x PWM, 4 PWM with current feedback) |
4 x CAN 1 x LIN 1 x RS 232 |
EN ISO 13849 PL d* |
CODESYS® C-programming (Matlab Simulink I/O Blocklib available) |
TTC 32S |
16-bit, 80 MHz |
14 inputs (analog & timer) 16 outputs (digital, voltage, PVG and 8x PWM, 6 with current feedback) |
2 x CAN | EN ISO 13849 PL d* | C-programming (Matlab Simulink I/O Blocklib available) |
TTC 30SH |
16-bit 80 MHz |
14 inputs (analog & timer), 16 outputs (digital, voltage, PVG and 8x PWM, 6 with current feedback) |
1 x CAN | EN ISO 13849 PL c | C-programming (Matlab Simulink I/O Blocklib available) |
TTConnect 616CS |
3 cores 32 bit 300 MHz |
Not applicable |
6 x 100BASE-T1 BroadR-Reach® 1 x 100BASE-TX Ethernet |
Not applicable |
Not applicable „plug & play“ solution via TTC Downloader |
*available for C-programming only |
Product | CPU | Number I/Os | Field Bus / Interfaces | Safety Certifcation / SIL Level | Programming Support |
---|---|---|---|---|---|
TTC 48XS |
16/32 bit, 80 MHz |
28 inputs (analog & digital), 20 outputs (8x PWM) |
1 x CAN | EN ISO 13849 PL d |
Slave software preinstalled – attached to a master controller via CANopen as slave unit |
TTC 30XSH |
16/32 bit, 80 MHz |
14 inputs (analog & timer), 16 outputs (digital, voltage, PVG and 8 x PWM, 6 with current feedback) |
1 x CAN | EN ISO 13849 PL c |
Slave software preinstalled – attached to a master controller via CANopen Safety as slave unit |
Our web-based service area operated by TTControl contains various program examples, latest documentation, workshop documents, current releases and necessary SW tools to jumpstart development.
This product is supplied by TTControl and distributed for the automotive market by TTTech Auto. For software updates and other technical information, visit the TTControl service area. If you need access, please get in touch with your TTTech Auto sales contact.
Service Area
For further information, including price and availability, please contact products@tttech-auto.com.
Visit the ECUs & Displays Service Area